Raytheon ASR-10SS MKII vendor-specific content of I002/050 Station Configuration Status.
More...
|
| enum | ast_asr10ss_dm_rotation_t { AST_ASR10SS_DM_ROT_UNKNOWN = 0
, AST_ASR10SS_DM_ROT_ROTATING = 1
, AST_ASR10SS_DM_ROT_STOPPED = 2
, AST_ASR10SS_DM_ROT_INVALID = 3
} |
| | Drive motor rotation status (ASR-10SS MKII). More...
|
| enum | ast_asr10ss_ups_mode_t { AST_ASR10SS_UPS_MODE_UNKNOWN = 0
, AST_ASR10SS_UPS_MODE_INVERTER = 1
, AST_ASR10SS_UPS_MODE_BYPASS = 2
, AST_ASR10SS_UPS_MODE_MAINTENANCE = 3
} |
| | UPS operating mode (ASR-10SS MKII). More...
|
| enum | ast_asr10ss_eng_gen_role_t { AST_ASR10SS_ENGGEN_UNKNOWN = 0
, AST_ASR10SS_ENGGEN_RUN = 1
, AST_ASR10SS_ENGGEN_STOP = 2
, AST_ASR10SS_ENGGEN_INVALID = 3
} |
| | Engine generator role (ASR-10SS MKII). More...
|
| enum | ast_asr10ss_site_power_t { AST_ASR10SS_SITE_PWR_UNKNOWN = 0
, AST_ASR10SS_SITE_PWR_COMMERCIAL = 1
, AST_ASR10SS_SITE_PWR_GENERATOR = 2
, AST_ASR10SS_SITE_PWR_BATTERY = 3
} |
| | Site power source (ASR-10SS MKII). More...
|
Raytheon ASR-10SS MKII vendor-specific content of I002/050 Station Configuration Status.
- Format:
- Variable length Data Item, extendible, up to 16 octets. Each octet carries a FX bit (bit 1): FX = 1 indicates extension, FX = 0 terminates the Data Item.
- Structure:
- Bytes 1-10 share the layout of the base ASR-10SS extension (see Data Item I002/050 - Station Configuration Status (ASR-10SS extension of I002/050)); the subsystem Mode / Role / Condition fields of bytes 1, 2, 6, 7, 8 and 9 reuse ast_asr10ss_mode_t, ast_asr10ss_role_t and ast_asr10ss_condition_t. Note that the MKII ICD decodes Condition value 11 as Degraded (the base ASR-10SS ICD decodes it as Invalid). Bytes 11-16 differ from the base layout:
- Byte 11: Selected Ethernet (0=LAN A, 1=LAN B), SCDI A/B UPS Active, RDF SDT/SIU Condition
- Byte 12: Summary Status (treated as a Condition) and shelter alarms (fire, intrusion, smoke, temperature, wind velocity)
- Byte 13: Antenna Condition, Drive Motor A Overcurrent and Rotation
- Byte 14: Drive Motor B Overcurrent and Rotation, Azimuth Data Generator X/Y Condition
- Byte 15: UPS Condition / Mode / Battery Condition
- Byte 16: Engine Generator #1/#2 Role, Site Power Source
- Note
- 902 is an internal data item number; it is displayed to users as I002/050. The standard I002/050 (application dependent bits) is left unchanged. Selected by the ASR-10SS MKII UAP.
-
Reference: asr10ss-mk2.md (FRN 6)
◆ ast_dataitem_002_902_get_size
Get size function for I002/902.
◆ ast_asr10ss_dm_rotation_t
Drive motor rotation status (ASR-10SS MKII).
| Enumerator |
|---|
| AST_ASR10SS_DM_ROT_UNKNOWN | Unknown.
|
| AST_ASR10SS_DM_ROT_ROTATING | Rotating.
|
| AST_ASR10SS_DM_ROT_STOPPED | Stopped.
|
| AST_ASR10SS_DM_ROT_INVALID | Invalid.
|
◆ ast_asr10ss_eng_gen_role_t
Engine generator role (ASR-10SS MKII).
| Enumerator |
|---|
| AST_ASR10SS_ENGGEN_UNKNOWN | Unknown.
|
| AST_ASR10SS_ENGGEN_RUN | Run.
|
| AST_ASR10SS_ENGGEN_STOP | Stop.
|
| AST_ASR10SS_ENGGEN_INVALID | Invalid.
|
◆ ast_asr10ss_site_power_t
Site power source (ASR-10SS MKII).
| Enumerator |
|---|
| AST_ASR10SS_SITE_PWR_UNKNOWN | Unknown.
|
| AST_ASR10SS_SITE_PWR_COMMERCIAL | Commercial.
|
| AST_ASR10SS_SITE_PWR_GENERATOR | Generator.
|
| AST_ASR10SS_SITE_PWR_BATTERY | Battery.
|
◆ ast_asr10ss_ups_mode_t
UPS operating mode (ASR-10SS MKII).
| Enumerator |
|---|
| AST_ASR10SS_UPS_MODE_UNKNOWN | Unknown.
|
| AST_ASR10SS_UPS_MODE_INVERTER | Inverter.
|
| AST_ASR10SS_UPS_MODE_BYPASS | Bypass.
|
| AST_ASR10SS_UPS_MODE_MAINTENANCE | Maintenance.
|
◆ ast_dataitem_002_902_decode()
Decode function for I002/902.
◆ ast_dataitem_002_902_get_detail_html()
| void ast_dataitem_002_902_get_detail_html |
( |
char * | detail, |
|
|
const size_t | detail_size, |
|
|
const ast_dataitem_t | di ) |
Get detail function for I002/902.
◆ ast_dataitem_002_902_get_summary()
| void ast_dataitem_002_902_get_summary |
( |
char * | summary, |
|
|
const size_t | summary_size, |
|
|
const ast_dataitem_t | di ) |
Get summary function for I002/902.